Белый фанкойл tongyi n-mfp
Tongyi n-mfp series energy efficient fan coil units: style, power and comfort for all rooms

Tongyi n-mfp series energy efficient fan coil units: style, power and comfort for all rooms

All prices are quoted excluding VAT and do not include delivery costs
The product is available for order in Montenegro, Serbia, Croatia, Slovenia, Germany
Category:
Tongyi brand logo with red Chinese character

TONGYI fan coil units are a modern and energy efficient solution for air conditioning and space heating. Thanks to their high-quality components, such as hydrophilic aluminum fins and copper tubes, they provide maximum heat transfer with minimum energy consumption.

Models of varying wattage will suit both small rooms and large office spaces:

  • N-MFP-34TM(A): ideal for rooms up to 20 m² – perfect for a bedroom or study.
  • N-MFP-51TM(A): suitable for rooms of 20 to 30 m², such as living rooms or children’s rooms.
  • N-MFP-68TM(A): suitable for rooms from 30 to 40 m², such as large bedrooms or kitchens.
  • N-MFP-85TM(A): optimal for spaces of 40 to 50 m², such as spacious living rooms or conference rooms.
  • N-MFP-102TM(A): can handle spaces of 50 to 60 m², ideal for open plan offices.
  • N-MFP-136TM(A): efficiently serves areas of 60 to 80 m², suitable for restaurants or stores.
  • N-MFP-170TM(A): Designed for spaces from 80 to 100 m², e.g. large conference rooms.
  • N-MFP-204TM(A): works in spaces from 100 to 120 m², such as sports halls.
  • N-MFP-238TM(A): the leader in its class, covers areas of more than 120 m², ideal for large offices and commercial facilities.
*Principles of power calculation for premises

Refrigeration:

For every 10 m² of floor space, approximately 1 kW of cooling capacity is required if the ceiling height is standard (2.5-2.8 m) and the thermal insulation complies with the regulations.

Heating:

Heating requires approximately 100 W per m², which corresponds to 2 kW for 20 m², 3 kW for 30 m² and so on.

Each model features intuitive controls and quiet operation, making them indispensable for creating a comfortable microclimate.

TONGYI model fan coil units operate on the principle of heat exchange using water as the heat transfer medium, so they require a heat pump.

Why don’t fan coil units operate independently?

Fan coil units do not generate heat or cold by themselves. Their task is to efficiently transfer heat energy from the heat transfer medium (water) to the room air through a heat exchanger.

What it’s good for:

  • This approach makes the system flexible: one heat pump can serve several fancoils in different rooms.
  • Can be installed in rooms of different sizes and purposes (living room, bedroom, office).

Fan coil N-MFP-34TM(A) / N-MFP-51TM(A) / N-MFP-68TM(A) / N-MFP-85TM(A) / N-MFP-102TM(A) / N-MFP-136TM(A) / N-MFP-170TM(A) / N-MFP-204TM(A) / N-MFP-238TM(A) specifications

N-MFP-34TM(A) N-MFP-51TM(A) N-MFP-68TM(A) N-MFP-85TM(A) N-MFP-102TM(A) N-MFP-136TM(A) N-MFP-170TM(A) N-MFP-204TM(A) N-MFP-238TM(A)
PRICE € 430 440 450 460 470 480 490 500 510
Overall dimensions TM mm 858*250*595 908*250*595 1058*250*595 1208*250*595 1258*250*595 1608*250*595 1758*250*595 1908*250*595 2058*250*595
TA mm 608*235*495 658*235*495 808*235*495 958*235*495 1008*235*495 1358*235*495 1508*235*495 1658*235*495 1808*235*495
Lifting installation Length mm 583 633 783 933 983 1333 1483 1633 1783
Width mm 220 220 220 220 220 220 220 220 220
Condensate outlet length and diameter mm 31*Ø21 31*Ø21 31*Ø21 31*Ø21 31*Ø21 31*Ø21 31*Ø21 31*Ø21 31*Ø21
Number of Motor Unit 1 1 1 1 1 2 2 2 2
Number of wind wheels Unit 2 2 2 2 2 4 4 4 4
Floor standing type fan coil unit
Air intake grille specifications (length) Entrance grille left 283mm Unit 1 1 1 1 1 1 1
Inlet grille right 283mm Unit 1 1 1 1 1 1 1
Inlet grille 350mm Unit 2 2 1 2 2 3 3
Number of air intake grilles Unit 2 2 2 2 3 4 4 5 5
Air inlet filter specifications (length) Filter 240mm Unit 2 2 2 2 2 2 2
Filter 320mm Unit 2 2 1 2 2 3 3
Number of air inlet filters Unit 2 2 2 2 3 4 4 5 5
Air outlet grille specifications (length) Air outlet grille 200mm Unit 1 3 2 1 3 3 2 1
Air outlet grille 350mm Unit 1 1 2 1 2 3 4 5
Number of Air outlet grille Unit 2 3 3 3 4 5 5 5 5
Decorative strip on the return air inlet Yes Yes
Air outlet size (length and width) mm 546*115 496*115 746*115 896*115 946*115 1296*115 1446*115 1596*115 1746*115
Return air size (length and width) mm
Evaporator length width and height mm 451*66*200 501*66*200 651*66*200 801*66*200 851*66*200 1201*66*200 1651*66*200
Number of roots Unit 24 24 24 24 24 24 24 24 24
Number of rows Unit 3 3 3 3 3 3 3 3 3
Number of inlet and outlet pipes 3 inlet pipes and 3 outlet pipes 3 inlet pipes and 3 outlet pipes 3 inlet pipes and 3 outlet pipes 3 inlet pipes and 3 outlet pipes 3 inlet pipes and 3 outlet pipes 3 inlet pipes and 3 outlet pipes 6 inlet pipes and 6 outlet pipes 6 inlet pipes and 6 outlet pipes 6 inlet pipes and 6 outlet pipes
Fin gap mm 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2
Pipe distance mm 25 25 25 25 25 25 25 25 25
Pipe diameter mm Ø9.52 Ø9.52 Ø9.52 Ø9.52 Ø9.52 Ø9.52 Ø9.52 Ø9.52 Ø9.52
Fin type corrugated sheet corrugated sheet corrugated sheet corrugated sheet corrugated sheet corrugated sheet corrugated sheet corrugated sheet corrugated sheet
Inlet and outlet pipe specifications (inner groove thread) ZG3/4 ZG3/4 ZG3/4 ZG3/4 ZG3/4 ZG3/4 ZG3/4 ZG3/4 ZG3/4

Established in 1999, Guangdong Tongyi Heat Pump Science and Technology Co., Ltd is one of the first and most professional heat pump manufacturers in China. Tongyi is committed to being a reliable partner, establishing the highest quality standards to ensure product stability and safety. Tongyi products are always at the forefront of
energy efficiency.
For over 20 years of development, Tongyi has gained a high reputation in quality and reliability. Tongyi has one of the most stringent control mechanisms in place for its manufacturing processes and product quality. It has successfully obtained most of the world well known certificates, including CE, EMC, RoHS, LVD, EMD, RED, ERP, IEC, ETL, SASO, CCC, ETC for its products and ISO9001, ISO14001, ISO45001 approvals for the production management.