Стиральная машина под бойлером у окна

Installation of a Tesy 260 L Water Heater with Heat Pump

About the Project

Task: install a 260-liter water heater with an integrated heat pump in a small utility room — next to the washing machine — without losing functionality and with a neat final appearance.

Implementation time: 2 working days.


Day 1. A Metal Structure for a Load of 370+ kg

A 260-liter water heater, when full, weighs more than 370 kg. Standard solutions don’t work here — a load-bearing structure tailored to the specific room is required.

We designed and built a metal frame from 40×40 mm profile: the upper platform for the water heater, the lower niche for the washing machine. The structure was welded, primed, and coated with weather-resistant paint. Installation was carried out with level alignment and precise fitting to the room’s dimensions — all in a single day.

  • Fabrication of the metal structure
  • Installing the water heater on the platform
  • Water supply and sewage connections
  • Electrical connection with a 16A (type C) circuit breaker

Day 2. Installation and Connection

  • Routing the heat pump’s air ducts outside through the wall (flexible 150 mm diameter ducts)
  • Installing sliding wardrobe-style doors to conceal all utilities
  • Commissioning and testing

Heat Pump vs. a Regular Water Heater: the Difference in Your Bill

A regular electric water heater works in a straightforward way: 1 kW consumed equals 1 kW of heat produced. A heat pump extracts heat from the air and transfers it to the water — electricity is used only to run the compressor, not for heating as such.

The Tesy Aquathermica ECO 260 has a coefficient of performance (CoP) of 3.6. This means:

  • The compressor consumes 0.7 kW (3.1 A × 230 V)
  • The output is 2.5 kW of thermal energy
  • Savings compared to a regular water heater — up to 70%

For a family of 4, annual consumption would be 1,136 kWh instead of approximately 3,800 kWh for a standard electric water heater.


How It Works Technically

Heat pump + backup heating element

The main work is done by the heat pump (3.1 A compressor). The built-in 1.5 kW (6.5 A) electric heater switches on only in two cases: when quick top-up heating is needed during increased water use, or for automatic anti-Legionella disinfection. In normal mode, the heating element does not operate.

When both components work simultaneously, the total current is 9.6 A, and the maximum power consumption is 2.2 kW. For comparison, an instant water heater of similar capacity would require 6–9 kW.

Why standard wiring is sufficient

The 16A circuit breaker provides a margin of 6.4 A above the maximum current — enough to prevent false tripping from starting currents. The cable is copper, 2.5 mm², a standard cross-section. No wiring upgrade was needed.

Operation at sub-zero temperatures

The heat pump operates with incoming air temperatures down to −10°C, allowing it to be installed in unheated utility rooms.

Temperature and safety

Maximum heating temperature — 75°C. This covers hot water supply needs and provides automatic thermal disinfection.

Refrigerant and energy efficiency class

The R513a refrigerant has a global warming potential (GWP) of 573 — half that of the widely used R134a. Energy class A+ under the European classification: annual consumption of 1,136 kWh confirmed under the standard load profile for a family of 4.


Summary

In 2 working days, a complete water-supply unit was fitted into a small utility room: a 260-liter water heater with heat pump, a washing machine, and all connections — all concealed behind sliding doors. No electrical upgrade was needed. The metal frame made from 40×40 mm profile holds a total load of about 450 kg (water heater filled with water) and is maintenance-free.

Electricity consumption for hot water dropped from approximately 3,800 to 1,136 kWh per year.

Want a Similar Solution?

Contact us via the contact form or on WhatsApp or call +382 68 584 699.

Share your love